e.g.

    Fluorine

    Chemical structure of PubChem CID 24524

    Risk Level Help

    Chemical Substance Information

    • PubChem CID: 24524
    • CAS: 7782-41-4
    • UN NO: 1045
    • EC NO: 231-954-8
    • Safety Data Sheet: Link
    • SMILES: FF

    Hazard Assessment Overview Help

    Hazard Sunburst Chart Legend

    Hazard Assessment Summary Table Help CSV format XLSX format
    Reset


    Assessment Type Carcinogenicity Mutagenicity Reproductive Toxicity Developmental Toxicity Endocrine Disruption
    Hazard Assessment Level
    Insufficient data
    for classification
    Medium
    Medium
    Medium
    Insufficient data
    for classification
    Loading
    Assessment Type Acute Toxicity Systemic Toxicity - Single Dose Systemic Toxicity - Repeated Dose Neurotoxicity - Single Dose Skin Sensitization Respiratory Sensitization Skin Irritation Eye Irritation
    Hazard Assessment Level
    Very High
    Medium
    Insufficient data
    for classification
    Insufficient data
    for classification
    Insufficient data
    for classification
    Insufficient data
    for classification
    Very High
    Very High
    Loading
    Assessment Type Acute Aquatic Toxicity Chronic Aquatic Toxicity
    Hazard Assessment Level
    Insufficient data
    for classification
    Insufficient data
    for classification
    Loading
    Assessment Type Persistence Bioaccumulation
    Hazard Assessment Level
    Very High
    Insufficient data
    for classification
    Assessment Type Reactivity Flammability
    Hazard Assessment Level
    High
    Insufficient data
    for classification
    Loading

    Hazard Diagnostic Modules

    The Hazard Diagnostic Module consists of the following four computational chemistry methods. The predicted toxicity alerts are for reference only and should be evaluated together with other available data.

    1. Substructure Alerts
    2. Similarity Alerts
    3. Read-Across
    4. Classification Models

    SMARTS Pattern Endpoint Source Author Journal Reference
    Loading
    Loading
    Loading

    Physical and Chemical Properties

    Property Value Source
    Boiling Point -188.111 °C
    As reported: -306.6 °F at 760 mmHg (EPA, 1998)
    Other sources (4)
    • -188.13 °C — Hazardous Substances Data Bank (HSDB)
    • -188 °C — ILO-WHO International Chemical Safety Cards (ICSCs)
    • -188.12 °C (-188.12 °C @760 [mm Hg]) — PAC Chemical Database, U.S. Department of Energy
    • -188.333 °C (-307 °F) — The National Institute for Occupational Safety and Health (NIOSH)
    CAMEO Chemicals
    Melting Point -219.611 °C
    As reported: -363.3 °F (EPA, 1998)
    Other sources (3)
    • -219.67 °C (-219.67 °C (triple point)) — Hazardous Substances Data Bank (HSDB)
    • -219 °C — ILO-WHO International Chemical Safety Cards (ICSCs)
    • -219.444 °C (-363 °F) — The National Institute for Occupational Safety and Health (NIOSH)
    CAMEO Chemicals
    Vapor Pressure 101.325 kPa
    As reported: 760 mmHg at -306.2 °F (EPA, 1998)
    Other sources (4)
    • 101.325 kPa (760 mm Hg at 85 K) — Hazardous Substances Data Bank (HSDB)
    • 99.9915 kPa (750 [mm Hg] @-188.3 °C) — PAC Chemical Database, U.S. Department of Energy
    • Vapor pressure = 5X10+6 mm Hg at 25 °C /Extrapaloted/ — Hazardous Substances Data Bank (HSDB)
    • >1 atm — The National Institute for Occupational Safety and Health (NIOSH)
    CAMEO Chemicals
    Solubility Reacts with water (NIOSH, 2024)
    Other sources (4)
    • Decomposes in water — Hazardous Substances Data Bank (HSDB)
    • Soluble in water with decomposition, forming hydrofluoric acid. — Hazardous Substances Data Bank (HSDB)
    • Solubility in water: reaction — ILO-WHO International Chemical Safety Cards (ICSCs)
    • Reacts — The National Institute for Occupational Safety and Health (NIOSH)
    CAMEO Chemicals
    Density 1.5127 at -306.6 °F (EPA, 1998) - Denser than water; will sink
    Other sources (6)
    • 1.5127 at -188.13 °C (liquid) — Hazardous Substances Data Bank (HSDB)
    • Saturated vapor density: 0.36850 lb/cu ft at -305 °F — Hazardous Substances Data Bank (HSDB)
    • Density = 1.667 g/L at 25 °C — Hazardous Substances Data Bank (HSDB)
    • 1.5127 at -306.2 °F — Occupational Safety and Health Administration (OSHA)
    • 1.553 @25 °C — PAC Chemical Database, U.S. Department of Energy
    • 1.31(relative gas density) — The National Institute for Occupational Safety and Health (NIOSH)
    CAMEO Chemicals

    Source: PubChem

    Safer Alternatives

    Safer alternatives are referenced from current safer chemical databases and software logic, divided into the following three categories:

    1. The system compiles industrial uses of chemicals from the US EPA ChemView database and integrates them with the US EPA Safer Chemical Ingredients to create a safer alternatives list for each chemical. Chemicals may have multiple industrial uses, so the system uses an accordion-style display. Click the 'Suggested Safer Alternatives' tab to expand the table. If the use is broad (e.g., 'Commercial use'), the list may include more specific uses (e.g., 'Solvent'). If no information is available, refer to 'By Industrial Use (Full List)' for manual filtering.
    2. Categorized by industrial use (full list). This list contains safer chemicals for industrial uses, not necessarily replacements for the chemical on this page. You may filter by industrial use via the search bar at the top right of this tab, e.g., filter by 'Antioxidants'. Source: Safer Chemical Ingredients List
    3. Categorized by structural similarity, requiring:
      • Find chemicals with similar functional groups based on structural similarity (Tanimoto coefficient ≥ 0.8), likely having similar functions.
      • Chemicals identified as lower risk by risk assessment, such as level 3, level 4, or insufficient data.
      Practical substitution feasibility still requires domain knowledge and reference to physicochemical properties. For insufficient data (U), it means current hazard and risk assessment information is limited; thus, selection should be cautious and toxicology studies should be reviewed.
    4. Based on real-world case studies. Source: OECD SAAT

    Based on substructure, the system lists chemicals with risk levels 3 (usable but safer alternatives may be sought), 4 (safer chemicals), or insufficient data (U: not enough data to determine risk level). Information

    Name CAS Industrial Use Safety Risk Level Data Source Notes
    Name CAS Industrial Use Safety Notes
    Loading
    This chemical is not listed in the ZeroPM PFAS alternative assessment database.
    SUBSPORT+ substitution case stories

    Real-world substitution cases involving this chemical, from the SUBSPORT+ case story database (English records).

    Case Role of this chemical Alternative Sector Function Implementation Reason for substitution
    Fluorine as climate-neutral alternative to nitrogen trifluoride in photovoltaics Used as alternative
    • Fluorine (7782-41-4)
    Manufacture of computer, electronic and optical products, electrical equipment Other Other In use — Germany, 2009 skin/respiratory sensitizing ecotoxicity
    OECD SAAT alternative case studies

    Full list of OECD SAAT case studies (not filtered by chemical).

    Case Study Name Link Publish Date Publishing Organization Related Products Description