Searching, assessment, and screening system for safer alternative chemicals, GreenN (Green Next)
| Assessment Type | Carcinogenicity | Mutagenicity | Reproductive Toxicity | Developmental Toxicity | Endocrine Disruption |
|---|---|---|---|---|---|
| Hazard Assessment Level |
High |
High |
Insufficient data
|
Insufficient data
|
High |
| Assessment Type | Acute Toxicity | Systemic Toxicity - Single Dose | Systemic Toxicity - Repeated Dose | Neurotoxicity - Single Dose | Skin Sensitization | Respiratory Sensitization | Skin Irritation | Eye Irritation |
|---|---|---|---|---|---|---|---|---|
| Hazard Assessment Level |
Very High |
Medium |
Insufficient data
|
Insufficient data
|
High |
Insufficient data
|
Very High |
Very High |
| Assessment Type | Acute Aquatic Toxicity | Chronic Aquatic Toxicity |
|---|---|---|
| Hazard Assessment Level |
Very High |
Very High |
| Assessment Type | Persistence | Bioaccumulation |
|---|---|---|
| Hazard Assessment Level |
Insufficient data
|
Insufficient data
|
| Assessment Type | Reactivity | Flammability |
|---|---|---|
| Hazard Assessment Level |
Insufficient data
|
Insufficient data
|
The Hazard Diagnostic Module consists of the following four computational chemistry methods. The predicted toxicity alerts are for reference only and should be evaluated together with other available data.
| SMARTS Pattern | Endpoint | Source | Author | Journal Reference |
|---|
| Property | Value | Source |
|---|---|---|
| Boiling Point |
190 °C
As reported: Decomposes at 190 °C
|
Hazardous Substances Data Bank (HSDB) |
| Melting Point |
126 °C
Other sources (1)
|
Human Metabolome Database (HMDB) |
| Vapor Pressure |
0.00011999 kPa
As reported: 0.0009 [mmHg]
Other sources (1)
|
Haz-Map, Information on Hazardous Chemicals and Occupational Diseases |
| Solubility |
0 mg·L⁻¹
As reported: In water, 1.5 g/100 mL (15,000 mg/L)
Other sources (2)
|
Hazardous Substances Data Bank (HSDB) |
| Partition Coefficient (LogP) |
0.82
As reported: 0.820
Other sources (1)
|
Human Metabolome Database (HMDB) |
Source: PubChem
Safer alternatives are referenced from current safer chemical databases and software logic, divided into the following three categories:
Based on substructure, the system lists chemicals with risk levels 3 (usable but safer alternatives may be sought), 4 (safer chemicals), or insufficient data (U: not enough data to determine risk level). Information
| Name | CAS | Industrial Use | Safety | Notes |
|---|
Real-world substitution cases involving this chemical, from the SUBSPORT+ case story database (English records).
| Case | Role of this chemical | Alternative | Sector | Function | Implementation | Reason for substitution |
|---|---|---|---|---|---|---|
| Ultrasound as alternative to biocides in cooling water application | Substituted | Non-chemical alternative Ultrasound device | Electricity, steam, gas water supply and sewage treatment | Biocide | Full capacity — 2006 | skin/respiratory sensitizing |
| Controlled hydrodynamic cavitation as alternative to chemical biocides and antiscaling agents | Substituted | Non-chemical alternative Technological alternative using patented device for controlled hydrodynamic cavitation as active component and a filtration unit as auxiliary unit. | General manufacturing, e.g. machinery, equipment, vehicles, other transport equipment Other | Biocide | In use | skin/respiratory sensitizing ecotoxicity |
Full list of OECD SAAT case studies (not filtered by chemical).
| Case Study Name | Link | Publish Date | Publishing Organization | Related Products | Description |
|---|