Searching, assessment, and screening system for safer alternative chemicals, GreenN (Green Next)
| Assessment Type | Carcinogenicity | Mutagenicity | Reproductive Toxicity | Developmental Toxicity | Endocrine Disruption |
|---|---|---|---|---|---|
| Hazard Assessment Level |
High |
High |
Insufficient data
|
Insufficient data
|
Insufficient data
|
| Assessment Type | Acute Toxicity | Systemic Toxicity - Single Dose | Systemic Toxicity - Repeated Dose | Neurotoxicity - Single Dose | Skin Sensitization | Respiratory Sensitization | Skin Irritation | Eye Irritation |
|---|---|---|---|---|---|---|---|---|
| Hazard Assessment Level |
Insufficient data
|
Insufficient data
|
Insufficient data
|
Insufficient data
|
Insufficient data
|
Insufficient data
|
Insufficient data
|
Insufficient data
|
| Assessment Type | Acute Aquatic Toxicity | Chronic Aquatic Toxicity |
|---|---|---|
| Hazard Assessment Level |
Insufficient data
|
Insufficient data
|
| Assessment Type | Persistence | Bioaccumulation |
|---|---|---|
| Hazard Assessment Level |
Insufficient data
|
Insufficient data
|
| Assessment Type | Reactivity | Flammability |
|---|---|---|
| Hazard Assessment Level |
Insufficient data
|
Insufficient data
|
The Hazard Diagnostic Module consists of the following four computational chemistry methods. The predicted toxicity alerts are for reference only and should be evaluated together with other available data.
| SMARTS Pattern | Endpoint | Source | Author | Journal Reference |
|---|
| Property | Value | Source |
|---|---|---|
| Melting Point | 212-220 °C | Hazardous Substances Data Bank (HSDB) |
| Solubility |
Solubility at 25 °C in: methanol 0.25 g/100 g; ethanol 0.07 g/100 g; acetone < 0.1 g 100 g; benzene < 0.1 g/100 g.
Other sources (1)
|
Hazardous Substances Data Bank (HSDB) |
| Density |
1.33 @ 25 °C/4 °C
Other sources (1)
|
Hazardous Substances Data Bank (HSDB) |
Source: PubChem
Safer alternatives are referenced from current safer chemical databases and software logic, divided into the following three categories:
Based on substructure, the system lists chemicals with risk levels 3 (usable but safer alternatives may be sought), 4 (safer chemicals), or insufficient data (U: not enough data to determine risk level). Information
| Name | CAS | Industrial Use | Safety | Risk Level | Data Source | Notes |
|---|
| Name | CAS | Industrial Use | Safety | Risk Level | Data Source | Notes |
|---|
| Name | CAS | Industrial Use | Safety | Notes |
|---|
Real-world substitution cases involving this chemical, from the SUBSPORT+ case story database (English records).
| Case | Role of this chemical | Alternative | Sector | Function | Implementation | Reason for substitution |
|---|---|---|---|---|---|---|
| Fire-resistant and flame proof coating for polymeric thermoplastics and thermoset resins. | Used as alternative |
|
Building and construction work Manufacture of rubber products Manufacture of plastics products, including compounding and conversion | Flame retardant | Pilot study | ecotoxicity physical hazards CMR |
Full list of OECD SAAT case studies (not filtered by chemical).
| Case Study Name | Link | Publish Date | Publishing Organization | Related Products | Description |
|---|